Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
Typ I: 230/400V; 400/690V
Typ II Series; 230/400 V; 1000 V; Spare Arrester VPU II
VPU AC II
VPU AC II+III S
VPU AC II US series
VPU AC II F with integrated fuse
230/400V IoT
275 V / 20 kA
440 V / 20 kA
Optical status indicator
Optical status indicator & remote alert
Spare arrester
General ordering data
Version
Surge voltage arrester, Low voltage, TN-C, UP (L/N-PE) <1000 V
Order No.
2907870000
Type
VPU AC II+III 3 275/20 S
GTIN (EAN)
4099986189928
Qty.
1 pc(s).
Dimensions and weights
Depth
70 mm
Depth (inches)
2.756 inch
Height
99 mm
Height (inches)
3.898 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
246 g
Temperatures
Operating temperature
-40 °C...85 °C
Connection data, remote alert
Connection type
Screw connection
General data
Colour
grey
Design
Installation housing; 2TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Combined pulse UOC
6 kV
Discharge current (type III)
3 kA
Discharge current Imax (8/20µs) wire-PE
20 kA
Discharge current In (8/20µs) wire-PE
10 kA
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤100 A gG
Low voltage network
TN-C
Max. continuous voltage, Uc (AC)
275 V
Number of poles
3
Protection level UP (typ.)
<1000 V
Protection level Up at IN (L/N-PE)
≤ 1.25 kV
Protection level Up at IN (N-PE) (type III)
≤1 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II/III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
335 V
Voltage type
AC
Connection data
Conductor connection cross-section PE, solid, max.
35 mm²
Conductor connection cross-section PE, stranded, max.
35 mm²
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, max.
1.2 Nm
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
10 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
6 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
10 mm²
Guarantee
Time interval
5 years
Important note
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
Tender specification
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2907930000
Type:
VPU AC II+III 1+1 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-S, TT, UP (L/N-PE) <1000 V
Type of connection:
Screw connection
Order No.:
2907830000
Type:
VPU AC II+III 2 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-S, TN-C, UP (L/N-PE) <1000 V
Type of connection:
Screw connection
Order No.:
2907950000
Type:
VPU AC II+III 3+1 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-S, TT, UP (L/N-PE) <1000 V
Type of connection:
Screw connection
Order No.:
2907890000
Type:
VPU AC II+III 4 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-C, IT with N, IT without N, TN-S, UP (L/N-PE) <1000 V
Version
Surge voltage arrester, Low voltage, TN-C, UP (L/N-PE) <1000 V
Order No.
2907870000
Type
VPU AC II+III 3 275/20 S
GTIN (EAN)
4099986189928
Qty.
1 pc(s).
Depth
70 mm
Depth (inches)
2.756 inch
Height
99 mm
Height (inches)
3.898 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
246 g
Operating temperature
-40 °C...85 °C
Connection type
Screw connection
Colour
grey
Design
Installation housing; 2TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Pollution severity
2
Surge voltage category
III
Combined pulse UOC
6 kV
Discharge current (type III)
3 kA
Discharge current Imax (8/20µs) wire-PE
20 kA
Discharge current In (8/20µs) wire-PE
10 kA
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤100 A gG
Low voltage network
TN-C
Max. continuous voltage, Uc (AC)
275 V
Number of poles
3
Protection level UP (typ.)
<1000 V
Protection level Up at IN (L/N-PE)
≤ 1.25 kV
Protection level Up at IN (N-PE) (type III)
≤1 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II/III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
335 V
Voltage type
AC
Conductor connection cross-section PE, solid, max.
35 mm²
Conductor connection cross-section PE, stranded, max.
35 mm²
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, max.
1.2 Nm
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
10 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
6 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
10 mm²
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Approval/Certificate/Document of Conformity
Engineering Data
Tender specification
User Documentation
Catalogues
Catalogues in PDF-format
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2907930000
Type:
VPU AC II+III 1+1 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-S, TT, UP (L/N-PE) <1000 V
Type of connection:
Screw connection
Order No.:
2907830000
Type:
VPU AC II+III 2 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-S, TN-C, UP (L/N-PE) <1000 V
Type of connection:
Screw connection
Order No.:
2907950000
Type:
VPU AC II+III 3+1 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-S, TT, UP (L/N-PE) <1000 V
Type of connection:
Screw connection
Order No.:
2907890000
Type:
VPU AC II+III 4 275/20 S
Version:
Surge voltage arrester, Low voltage, TN-C, IT with N, IT without N, TN-S, UP (L/N-PE) <1000 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.